record THERMCORD – automatic linear door system with heat insulating properties
Drive Dimensions
|
|
THERMCORD D-STA |
THERMCORD E-STA |
Without side piece (depth x height) |
157 x 150 mm / 167 x 200 mm |
157 x 150 mm / 167 x 200 mm |
With side piece (depth x height) |
210 x 150 mm / 210 x 200 mm |
210 x 150 mm / 210 x 200 mm |
Adjustable parameters
|
Opening speed |
up to 0.75 |
up to 0.75 |
General technical specifications
|
Width of passage A |
800 – 3 000 mm |
800 – 2 500 mm |
Height of passage G |
max. 3 000 mm |
max. 3 000 mm |
Support beam length F |
2A+250 mm |
max.2A+125 mm |
Total height J |
G + 150 / 200 mm |
G + 150 / 200 mm |
Door leaf weight |
max. 2 x 120 kg |
max. 1 x 150 kg |
Door leaf weight DUO/RED |
max. 2 x 150 kg |
max. 1 x 150 kg |
Power supply voltage |
100 – 240 V AC, 50 / 60 Hz |
100 – 240 V AC, 50 / 60 Hz |
Rated power |
90 W |
90 W |
Power consumption |
max. 250 – 300 W |
max. 250 – 300 W |
Consumption in standby mode |
25 W |
25 W |
Thermal value UD |
up to 1.1 W / m2 K |
up to 1.1 W / m2 K |
Gearbox |
worm gear |
worm gear |
Drive |
toothed belt |
toothed belt |
Operating conditions
|
Ambient temperature |
− 15° to + 50° C |
− 15° to + 50° C |
Humidity range |
up to 85 % rel. humidity, non-condensing |
up to 85 % rel. humidity, non-condensing |
Functional safety
|
Standard compliance |
EN 16 005, DIN 18 650, EN 16 361 |
EN 16 005, DIN 18 650, EN 16 361 |