record AIR 290 – infrared sensor
General technical specifications
|
|
record AIR 290 |
Power supply voltage |
11 to 31 V DC |
Operating conditions
|
Ambient temperature |
–20 °C to +50 °C |
Type of protection |
IP 54 |
Functional safety
|
Standard compliance |
EN 16005:2012, DIN 18650:2005, ISO 13849-1: 2006 Kat. 2 PL b, |
Sensors & Control Units
|
Connected load |
<1.5 W |
Installation height (DIN 18650), max. |
3000 mm |
outstanding of the standards |
<4000 mm |
Detection capability (DIN 18650) |
Test body CA |
Max. fuse protection if separately supplied |
2.5 A |
Wavelength infrared |
870 nm |
Performance level |
PL „c“, Cat. 2 |
Response time, max |
< 500 ms |