record C 127 – Concealed underfloor drive for swing doors
Drive Dimensions
|
|
record C 127 Center |
Length |
710 (780 with ground housing) mm |
Height |
200 (270 with ground housing) mm |
Depth |
130 (150 with ground housing) mm |
Adjustable parameters
|
Opening angle |
Can be selected from 70° to 115° |
Open time |
Can be selected from 0 to 60 seconds |
Opening speed |
Can be selected from 3 to 20 seconds |
Closing speed |
Can be selected from 5 to 20 seconds |
General technical specifications
|
Electrical data |
230 V AC 50 / 60 Hz |
Power consumption |
13 W in standby mode, 67 W rated power |
Maximum torque |
50 (80 in the case of a reinforced “heavy” version) Nm |
Maximum moment of inertia of the door leaf |
65 (140 in the case of the reinforced “heavy” version) kgm2 |
Operating conditions
|
Ambient temperature |
− 15 °C to + 50 °C |
Humidity range |
Up to 85% relative humidity, non-condensing |
Wind load |
Designed for wind load zone 2 (25 m / s) |
Type of protection |
IP 67 |