en

record C 127 – Concealed underfloor drive for swing doors

Drive Dimensions
record C 127 Center
Length 710 (780 with ground housing) mm
Height 200 (270 with ground housing) mm
Depth 130 (150 with ground housing) mm
Adjustable parameters
Opening angle Can be selected from 70° to 115°
Open time Can be selected from 0 to 60 seconds
Opening speed Can be selected from 3 to 20 seconds
Closing speed Can be selected from 5 to 20 seconds
General technical specifications
Electrical data 230 V AC 50 / 60 Hz
Power consumption 13 W in standby mode, 67 W rated power
Maximum torque 50 (80 in the case of a reinforced “heavy” version) Nm
Maximum moment of inertia of the door leaf 65 (140 in the case of the reinforced “heavy” version) kgm2
Operating conditions
Ambient temperature − 15 °C to + 50 °C
Humidity range Up to 85% relative humidity, non-condensing
Wind load Designed for wind load zone 2 (25 m / s)
Type of protection IP 67
Loading...